华为多路径软件UltraPath

检查多路径是否安装。

rpm -qa|grep UltraPath

查看UltraPath软件版本

upadmin show version

查看物理路径状态。

#upadmin show path

查看虚拟磁盘信息。

#upadmin show vlun

查看逻辑路径状态。

#upadmin show vlun

查看多路径配置。

#upadmin show upconfig

卸载UltraPath

root@db1 \~# rpm -e UltraPath

The running service is deleted successfully.

The boot service is removed successfully.

The UltraPath files are deleted successfully.

UltraPath driver package has been successfully removed from your system.

Restart the system.

root@db1 \~# upadmin show version

Software Version : 31.02.024

Driver Version : 31.02.024

root@db1 \~# upadmin show upconfig

=======================================================

UltraPath Configuration

=======================================================

Basic Configuration

Working Mode : load balancing within controller

LoadBalance Mode : min-queue-depth

Loadbanlance io threshold : 100

LUN Trespass : off

Advanced Configuration

Io Retry Times : 10

Io Retry Delay : 0

Faulty path check interval : 10

Idle path check interval : 60

Failback Delay Time : 60

Io Suspension Time : 60

Max io retry timeout : 1800

Performance Record : off

Pending delete period of obsolete paths : 28800

Path reliability configuration

Timeout degraded statistical time : 600

Timeout degraded threshold : 1

Timeout degraded path recovery time : 1800

Frequent timeout degraded statistical time : 86400

Frequent timeout degraded threshold : 3

Frequent timeout degraded path recovery time : 86400

Intermittent IO error degraded statistical time : 300

Min. I/Os for intermittent IO error degraded statistical : 5000

Intermittent IO error degraded threshold : 20

Intermittent IO error degraded path recovery time : 1800

Intermittent fault degraded statistical time : 1800

Intermittent fault degraded threshold : 3

Intermittent fault degraded path recovery time : 3600

High latency degraded statistical time : 300

High latency degraded threshold : 1000

High latency degraded path recovery time : 3600

Sensitive delayed degraded threshold : 0

Sensitive delayed degraded recovery time : 120

HyperMetro configuration

HyperMetro Primary Array SN : 2102350HYL10H6000020

HyperMetro WorkingMode : read write within primary array

HyperMetro Split Size : 128MB

HyperMetro Load Balance Mode : round-robin

root@db1 \~#

root@db1 \~# upadmin show path


Path ID Initiator Port Array Name Controller Target Port Path State Check State Port Type Port ID

0 10000090fa81c6ef Huawei.Storage-1F 0A 2080446a2ef573be Normal -- FC CTE0.A.H0

1 10000090fa81c6ef Huawei.Storage-1F 0B 2090446a2ef573be Normal -- FC CTE0.B.H0



Path ID Initiator Port Array Name Controller Target Port Path State Check State Port Type Port ID

2 10000090fa81c6ef Huawei.Storage-2F 0B 2091446a2ef573b5 Normal -- FC CTE0.B.H1

3 10000090fa81c6ef Huawei.Storage-2F 0A 2081446a2ef573b5 Normal -- FC CTE0.A.H1


root@db1 \~# upadmin check status


Checking path status:

Serverity Array Type Description

Critical 2102350HYL10H6000020 All path down All paths of LUN (wwn:6446a2e100f573b55c5a1ff100000010) are down.

Critical 2102350HYL10H6000020 All path down All paths of LUN (wwn:6446a2e100f573b55c5a462d00000011) are down.


Checking environment and config:

Pass


Checking HBA Information:

iscsi is not installed.

complete FC checking.

Pass

...................

root@db1 \~# rpm -e UltraPath-31.02.024-2.x86_64

The running service is deleted successfully.

The boot service is removed successfully.

The UltraPath files are deleted successfully.

UltraPath driver package has been successfully removed from your system.

Restart the system.

故障处理--重新安装

root@db1 CentOS# upadmin show version

Unable to detect UltraPath device node, exit

root@db1 \~# ./install.sh

complete iscsi checking.

complete FC checking.

Verify the UltraPath existence.

WARNING The UltraPath driver has been detected.

Do you want to uninstall it now?

<Y|N>:y

The UltraPath uninstallation starts.

The running service is deleted successfully.

The boot service is removed successfully.

The UltraPath files are deleted successfully.

UltraPath driver package has been successfully removed from your system.

Modify system configuration.file:/etc/iscsi/iscsid.conf,item:node.startup ,value: automatic

Modify system configuration.file:/etc/iscsi/iscsid.conf,item:node.session.timeo.replacement_timeout ,value: 1

Modify system configuration.file:/etc/modprobe.d/nxupmodules.conf,module:qla2xxx,item:qlport_down_retry,value:5

Modify system configuration.file:/etc/modprobe.d/nxupmodules.conf,module:lpfc,item:lpfc_nodev_tmo,value:5

Modify system configuration.file:/etc/systemd/system.conf,item:DefaultTimeoutStartSec,value:600s

If the operating system is installed on a local drive of the server, you are advised

to choose boot from local; if the operating system is installed on a SAN storage

system, you must choose boot from san. Please choose the boot type of your system:

<1>--boot-from-Local

<2>--boot-from-SAN

please input your select:1

Preparing... ########################################

Updating / installing...

UltraPath-31.02.024-2 ########################################

User configuration is saved successfully.

The boot service is installed successfully.

The running service is installed successfully.

************************************Attention************************************

* UltraPath would modify some parameters of HBA cards for better performace. If *

* UltraPath is installed for the first time, you may need to update the initrd *

* image before system reboot to make the modification take effect. *

*********************************************************************************

*********************************************************************************

* UltraPath will use the system hostname for alarm generation and automatic host*

* registration. Make sure that the system hostname is correctly configured.. *

*********************************************************************************

The installation is complete. Whether to restart the system now?

<Y|N>:y

问题1:alua not support告警

华为官网文档:Centos7.5系统自带多路径报错alua not support

Centos7.5系统自带多路径报错alua not support- 华为

相关推荐
爱写代码的森8 小时前
鸿蒙三方库 | harmony-utils之ImageUtil图片保存到本地详解
服务器·华为·harmonyos·鸿蒙·huawei
HLC++11 小时前
Linux的进程间通信
android·linux·服务器
华清远见IT开放实验室12 小时前
实验室建设案例 | 石家庄科技信息职业学院嵌入式实验室——从底层硬件到系统应用,一所应用型高校的嵌入式人才培养这样落地
linux·arm开发·stm32·嵌入式硬件·高校·实验室建设
白露与泡影13 小时前
Arthas 实战指南:从方法耗时定位到 JVM 变量热修改
服务器·jvm·c#
神奇霸王龙14 小时前
Claude Code屠榜:MiMo与Grok紧追Codex
服务器·网络·人工智能·gpt·ai·ai编程
Web极客码14 小时前
WordPress SEO优化:提升网站排名的13个关键步骤
服务器·seo·wordpress
groundhappy15 小时前
idalib安装和codex ida-mcp配置
linux·开发语言·python
通信小小昕16 小时前
Ubuntu 26.04 中文输入法安装
linux·运维·ubuntu
张小姐的猫17 小时前
【Linux】网络编程 —— HTTP协议(上)
linux·运维·服务器·网络·http·单例模式·策略模式
国科安芯17 小时前
星间光链路:AS32S601型抗辐射MCU在空间激光通信终端控制中的技术实现
服务器·网络·单片机·嵌入式硬件·物联网·安全·信息与通信